
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 7 - Jul 12
For Your Every Summer RSVP, with Code: SUMMER15
Description
Human BASP1 ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and pipette tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Tissue, homogenates, cell lysates and other biological fluids Preparation before testing: 1. Please take out the test kit from the refrigerator 10 minutes in
Product Specification
| Usage |
Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High-precision pipette and pipette tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37℃ constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Tissue, homogenates, cell lysates and other biological fluids Preparation before testing: 1. Please take out the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare a gradient standard working solution: Add 1 mL of universal diluent to the lyophilized standard. Let stand for 15 minutes to completely dissolve, then gently mix (concentration 20 ng/mL). Then dilute to the following concentrations: 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 20 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 10 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details. 3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a capture antibody against Brain Abundant, Membrane Attached Signal Protein 1 (BASP1). After incubation and washing, the assay is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of Brain Abundant, Membrane Attached Signal Protein 1 (BASP1) in the sample. Absorbance (OD) is measured at 450 nm using a microplate reader to calculate sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Human | |||||||||||||||||||||||||||||||||
| Synonym | Human Brain Abundant, Membrane Attached Signal Protein 1 ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Brain-enriched membrane attachment signaling protein 1, also known as BASP1, is encoded by the BASP1 gene. This gene encodes a membrane-bound protein with several transient phosphorylation sites and a PEST motif. The conservation of proteins with PEST sequences across species supports their functional significance. PEST sequences are often found in proteins with high turnover rates. The immunological characteristics of this protein are species-specific. This protein also undergoes N-terminal myristoylation. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.312-20 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Tissuehomogenates, celllysates and otherbiologicalfluids |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.0 ★★★★★
Based on 1923 reviews
Sort
Product Reviews
★★★★★ 5
Works great! Gets hot fast & water in tank lasts
Style: Steam Mop
Works great! Gets hot fast and the max amount of water it takes goes a long way in my home. I can clean several rooms and still have half of the water still in the tank. Awesome, easy to use, effective and great value for the price.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 6, 2026
★★★★★ 5
Will buy again
Style: Steam Mop
I’m pretty impressed with this steam mop. It cleans great, leaving no streaks. It’s easy to handle with its decent sized griped handle. It’s durable and easy to use. It’s sleek and lightweight with a pretty long cord. I highly recommend.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 20, 2026
★★★★★ 5
Great for price
Style: Steam Mop
Works well
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 6, 2026
★★★★★ 4
Needs a longer cord! But does the job well!
Style: Steam Mop
My only complaint is the cord is not long enough! I have to go around finding every outlet to plug it into to get my whole house clean.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 26, 2026
★★★★★ 3
You get what you pay for
Style: Steam Mop
It's just OK. It does get the job done, but poorly made and I don't expect it to last long. Unlike other steam mops I've had, this one leaves the floor wet. Plus the pad does not pick up any stuck-on gunk that the steam loosened. I had to go back and pick up a few pieces by hand. Instructions say to let the water tank air dry before storing, but the attached lid makes it hard to let air into the tank. In retrospect I should have spent a few dollars more and gotten a better unit.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 22, 2026
recommand products
B405C1 $894 100% FREE SHIP w/ COUPON Standard WHITE HEGA UNIT Allergy Machine Air Purifier B405-WH
447.50
EV9108-53 Everpure Costguard CG53-10 Water Filter Cartridge # DEV910853
61.04
GRO-75EN Pentair TLC Encapsulated Membrane 75gpd w/ Check Valve
148.00
41400008 / Hydrotech Sediment RO Filter S-FS-02
16.95
EV9771-00 $194 100% FREE SHIP w/ COUPONS Pentair Everpure 7CLM+ Chloramine Reduction Cart
194.86